ZMH Šukoplam K – Top Loading Log Boiler 50kW (170,600 BTU)

Brand:
SKU: SUKOM-K50
EAN:
Price: £3,300.00 +VAT
In Stock

ZMH Šukoplam K – Top Loading Log Boilers

The ZMH Šukoplam K is a high-quality top loading log boiler designed for efficient and reliable solid fuel heating. Manufactured from heavy-duty boiler-grade steel and compliant with EN 303-5 standards, it is ideal for residential and commercial heating systems. Fuel is manually loaded via a spacious upper door, while a mechanical draft regulator ensures controlled combustion and consistent performance.

Key Features

  • Power outputs from 20–50 kW
  • Suitable for wood and coal
  • Large top loading door
  • Heavy-duty boiler steel firebox
  • Mechanical draft regulator
  • EN 303-5 compliant
  • Max pressure: 2.5 bar
  • Operating temp: 90/70 °C

Available in outputs from 20–50 kW, durable boiler-grade steel construction, and compliance with EN 303-5 standards, making it ideal for reliable hot water production in residential and commercial applications.

📄 Installation & Operating Manual (PDF)

📄Šukoplam K 20 50 kW – Available Options 

Optional Flue kit Available

FUELS THAT CAN BE USED

  • Solid chunk fuels
  • Grain biomass, such as pellets
  • Coal & Wood

Need Technical Help or Advice?
Call the ZM Team we are here to Help: 0333 600 4460  or Email info@zmh.uk.com

(Delivery & Installation)
After any purchase, all customers are contacted by the ZM Customer Service Team, to coordinate your delivery and the pre install technical checks

Payment Options

  • Credit & Debit Card
  • Bank Transfer
  • Lease Purchase

Equipment Lease Purchase Application
We can offer lease purchase option on this item and to enquire simply use the “Quote / Question“ button option below and the ZM Customer Service Team will contact you to discuss the options.

Estimated Delivery: 1-3 Working Days

  • Need Help? 0333 600 4460
    Our dedicated customer service is here to help
  • Direct From Suppliers
    To UK Mainland

FEATURES

ZMH Šukoplam K – Top Loading Log Boilers

The ZMH Šukoplam K top loading log boiler is available in power outputs ranging from 20–50 kW and are designed for the combustion of solid lump fuels, including wood and coal. Fuel is manually loaded through a large, slanted upper loading door, allowing for easy and efficient refuelling.

The boiler firebox is manufactured from high-quality P265GH boiler steel, with plate thicknesses of 5 mm and 4 mm, while the boiler tubes are produced from P235GH TC1 steel, 4 mm thick, ensuring durability and long service life.

The boiler’s construction is fully compliant with European Standard SRPS EN 303-5. The boiler body is insulated with mineral wool to minimise heat loss, and the external casing is protected using a plasticising process for enhanced corrosion resistance and durability.

The ZMH Šukoplam K is designed for hot water production with an operating temperature regime of 90/70 °C and a maximum operating pressure of 2.5 bar.

Combustion air supply is controlled by a mechanical draft regulator, which operates a damper on the lower door to automatically increase or reduce airflow, ensuring stable and efficient combustion.

 

Model Nominal Output Fuel Type Max Pressure Operating Temp Application
Šukopalm K 20 20 kW Wood / Coal 2.5 bar 90/70 °C Residential
Šukopalm K 25 25 kW Wood / Coal 2.5 bar 90/70 °C Residential
Šukopalm K 30 30 kW Wood / Coal 2.5 bar 90/70 °C Residential / Light Commercial
Šukopalm K 40 40 kW Wood / Coal 2.5 bar 90/70 °C Commercial
Šukopalm K 50 50 kW Wood / Coal 2.5 bar 90/70 °C Commercial / Agricultural

 

Compliance & Installation Notice

The ZMH Šukoplam K boiler is manufactured in accordance with SRPS EN 303-5 European standards. Installation, commissioning, and servicing must be carried out by a qualified heating engineer and in accordance with all local building regulations and national standards.

The boiler is designed for use with approved solid fuels only. Incorrect fuel use or improper installation may affect performance, efficiency, and warranty validity. Please refer to the downloadable operating and installation manuals before use.

 

ADDITIONAL INFORMATION

ZMH Šukoplam K

Top Loading Log Boiler | 20–50 kW

The ZMH Šukoplam K is a robust and reliable top loading log boiler designed for efficient solid fuel combustion. Available in outputs from 20 kW to 50 kW, it is suitable for residential, commercial, and agricultural heating applications.

Fuel is manually loaded through a large, slanted upper door, ensuring ease of use and consistent combustion. The firebox is constructed from high-quality P265GH boiler steel, with reinforced plate thicknesses of up to 5 mm, providing excellent durability and long service life.

The boiler complies fully with European Standard EN 303-5 and features mineral wool insulation to minimise heat loss. The outer casing is protected by a plasticised coating, offering increased resistance to corrosion and wear.

Combustion air is regulated by a mechanical draft regulator, which automatically adjusts airflow via a damper on the lower door, ensuring stable and efficient operation.

The ZMH Šukoplam K operates within a 90/70 °C temperature regime and supports a maximum operating pressure of 2.5 bar, making it a dependable solution for hot water heating systems.

Key Features

  • Available outputs from 20–50 kW
  • Suitable for wood and coal solid fuels
  • Top loading design with large slanted loading door
  • Heavy-duty boiler-grade steel firebox
  • EN 303-5 compliant construction
  • Mechanical draft regulator for controlled combustion
  • Designed for 90/70 °C heating systems
  • Maximum operating pressure: 2.5 bar
  • Mineral wool insulated body for reduced heat loss
  • Durable plasticised outer casing
  • Suitable for closed heating systems

 

 

Feature Specification
Boiler Type Top Loading Log Boiler
Fuel Type Solid lump fuel (wood, coal)
Output Range 20 – 50 kW
Loading Method Manual, via slanted upper door
Firebox Material P265GH boiler steel
Firebox Thickness 5 mm / 4 mm
Boiler Tube Material P235GH TC1 steel
Boiler Tube Thickness 4 mm
Operating Temperature 90 / 70 °C
Maximum Operating Pressure 2.5 bar
Combustion Air Control Mechanical draft regulator with damper
Insulation Mineral wool
Casing Protection Plasticised finish
Standards Compliance SRPS EN 303-5